Recommended configurations of installation with Laddomat 21, termoregulatory valves, electroregulation 3 ways mixing valve, electronical regulation of the heating system and heating of DHW in range up to 100kW.
 |
1. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 3 adding thermoregulators |
 |
2. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 2 adding thermoregulators |
 |
3. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 3 adding thermoregulators |
 |
4. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 2 adding thermoregulators |
 |
5. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation |
 |
6. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation |
 |
7. Installation of boiler with 3 ways mixing valve, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation |
 |
8. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, opened expansion vessel, easy installation with 1 adding thermoregulator |
 |
9. Installation of boiler with Laddomat 21, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation |
 |
10. Installation of boiler with termoregulation mixing valve, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation |
 |
11. Installation of boiler with 3 ways mixing valve, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation |
 |
13. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, easy installation with 2 adding thermoregulators |
 |
14. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, easy installation with 2 adding thermoregulators |
 |
15. Installation of boiler with 3 ways mixing valve, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, installation with electronic regulation |
 |
16. Installation of boiler with Laddomat 21, two accumulation tanks, heating of DHW in buffer tank, one heating circuit, closed expansion vessel, installation with electronic regulation |
 |
17. Installation of boiler with 3 ways mixing valve, two accumulation tanks, heating of DHW in buffer tank, one heating circuit, closed expansion vessel, installation with electronic regulation |
 |
18. Installation of boiler with Laddomat 21, two accumulation tanks, two heating circuits, one for DHW in combination boiler, opened expansion vessel, installation with electronic regulation |
 |
19. Installation of boiler with Laddomat 21, three accumulation tanks, two heating circuits, heating of DHW in buffer tank, closed expansion vessel, easy installation with an adding thermoregulator |
 |
20. Installation of boiler with Laddomat 21, three accumulation tanks, two heating circuits, heating of DHW in buffer tank, closed expansion vessel, installation with electronic regulation |
 |
21. Installation of boiler with Laddomat 21, one accumulation tank, three heating circuits one for DHW in combination boiler, closed expansion vessel, installation with electronic regulation |
 |
22. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve |
 |
23. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve |
 |
24. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve |
 |
25. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve |
 |
26. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve |
 |
27. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve |
 |
28. Installation of two ATMOS boilers, with 3 ways mixing valves, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve |
 |
29. Installation of two ATMOS boilers, with termoregulation mixing valves, two heating circuits, one for DHW in combination boiler, closed expansion vessels, buffer tank min. 1000l, easy installation with adding thermoregulators, possible to heat by both boilers at the same time |
 |
30. Installation of two boilers with Laddomats 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators |
 |
31. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, installation with electronic regulation, switching the two boilers by zone valves |
 |
32. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, easy installation with adding thermoregulators, switching the two boilers by zone valves |
 |
33. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, easy installation with adding thermoregulators, switching the two boilers by zone valves |
 |
34. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, buffer tank, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve |
 |
35. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by zone valves |
 |
36. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, buffer tank, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves |
 |
37. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves |
 |
38. Installation of three boilers, each with 3 ways electronic mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators |
 |
39. Installation of three boilers, each with termoregulation mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the three boilers by zone valves |
 |
40. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, buffer tank, closed expansion vessels, installation with electronic regulation, switching the three boilers by zone valves |
 |
41. Installation of three boilers, each with 3 ways electronic mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation |
 |
42. Installation of three boilers, each with termoregulation mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves |