Wood Gasification Boilers

- Gasifying boilers for wood
Gasifying boilers for wood
The boilers are constructed for burning wood on the principle of generator gasifying with the use of a gas exhaust ventilator, which withdraws the combustion gases from the boiler, or leads air into the boiler.
The boiler body is produced as a weldment of 3-8 mm steel sheets. They comprise the fuel hopper, which is equipped at the bottom with a heatproof pipe fitting with longitudinal hole for the combustion gases and passage of gases. The burnout part of the multiple chamber furnace under the fuel hopper is equipped with ceramic pipe fittings. There is a vertical combustion gas duct in the back of the boiler body, which is equipped with a heating valve in the upper section. The upper part of the combustion gas duct is fitted with a gas exhaust outlet for connection to a chimney.
Adventages of Wood Gasification Boilers ATMOS
- Option to burn large pieces of wood
- Primary and secondary air is also preheated to a high temperature - higher effectiveness
- The ventilator automatically switches off when the fuel burns out.
- Easy servicing and cleaning
- Ceramic combustion space - high effectiveness
- Large fuel container
- Large space for ash (when burning wood you have to clean it once per week)
- Boiler without tube plate - easier cleaning
- Small size and low weight
- High quality
ENVIRONMENT
Reverse combustion and a ceramic combustion chamber enable perfect combustion with minimum polluting emissions. The boilers comply with environmentally-friendly product requirements according to Guideline No. 13/2002 of the Czech Ministry of Environment. They comply the European Standard EN 303-5 and all the boilers rate in class 3.
INSTALLATION
ATMOS boilers must be connected via the LADDOMAT 21 or ESBE thermoregulation valve to achieve keeping the minimum temperature of water returning to boiler at 65°C. The temperature of water exiting the boiler must be permanently kept between 80 - 90°C. The default configuration of all boilers includes a cooling circuit to prevent overheating. We recommend installing boilers with accumulation tanks.
CERTIFICATION
All ATMOS boilers are certified in testing laboratories for the individual countries of destination: State Testing Laboratory Brno, TÜV Munich - Germany, Lithuania, Ukraine, Sweden, Poland, Austria, Slovakia, Hungary according to current standards - EN 303-5.
Protected by patent.
The boilers ATMOS Generator DC 20GS, DC 25GS, DC 32GS and DC 40GS, are completely new types of boilers for wood. They are true LCV-generators.

- DC 18S, DC 22S, DC 25S, DC 32S,
DC 50S, DC 75SE, DC40SX,
ATMOS Drevoplyn

- DC 20GS, DC 25GS,
DC 32GS, DC 40GS,
ATMOS Generator

- Suction fan

- Cooling coil
Regulation of the Boilers
Electrical - mechanical - Power is controlled with a safety valve operated with the draught regulator, FR 124 type, which automatically opens or closes the safety valve according to a set output temperature of water (80 - 90°C), (except for DC50SE) instead of this, the boiler is equipped with a BELIMO servo flap with a spring. When setting the power regulator, much attention should be paid because the regulator has another important function other than power regulation - it also secures the boiler against overheating. A controlling thermostat located on the boiler panel regulates the fan according to a set temperature (75 - 85°C). A temperature lower by 5°C should be set on the controlling thermostat rather than on the FR 124 draught regulator.
The boiler runs at a reduced output even without a fan - heating is not lost when the electric power fails. At up to 70 percent of its rated output, the boiler can be operated without a ventilator.
Each boiler can be fitted with ATMOS ACD 01 equithermal controller. It takes a control of the heating system based on datas collected from external sensors and on time. It can control suction fan of the boiler as well.

LEGEND OF THE BOILER DIAGRAM
| 1. | Boiler drum | 14. | Fireproof and heat-resisting fitting - GS - rear face of round space |
|---|---|---|---|
| 2. | Filling door | 15 | Cleaning cover |
| 3. | Ash pan door | 16 | Orifice plate |
| 4. | Fan - pressure, exhaust (S) | 17 | Firing safety valve pull rod |
| 5. | Fireproof and heat-resisting fitting - nozzle | 18 | Thermometer |
| 6. | Control panel | 19 | Furnace orifice plate |
| 7. | Safety thermostat | 20 | Switch |
| 8. | Regulating safety valve | 22 | Power regulator - Honeywell FR124 |
| 9. | Fireproof and heat-resisting fitting - furnace side - GS | 23 | Cooling loop |
| 10. | Fireproof and heat-resisting fitting - GS - round space L+P | 24 | Fan thermostat |
| 11. | Sealing - nozzles | 25 | V. Door panel - Sibrall |
| 12. | Fireproof and heat-resisting fitting - half-moon | 26 | Door sealing - cord 18 x 18 |
| 13. | Firing safety valve | 27 | Waste gas thermostat |
Dimensions
| DC 15 E |
DC 18 S |
DC 22 S |
DC 25 S |
DC 32 S |
DC 40 SX |
DC 50 S |
DC 70 S |
DC 20 GS |
DC 25 GS |
DC 32 GS |
DC 40 GS |
DC 50 GSX |
DC 70 GSX |
DC 75SE |
DC 100 |
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | 1180 | 1180 | 1180 | 1180 | 1260 | 1260 | 1260 | 1380 | 1260 | 1260 | 1260 | 1410 | 1558 | 1648 | 1480 | 1590 |
| B | 630 | 770 | 970 | 970 | 970 | 970 | 1170 | 1170 | 770 | 970 | 970 | 970 | 1042 | 1068 | 1470 | 1180 |
| C | 590 | 590 | 590 | 590 | 670 | 670 | 670 | 670 | 670 | 670 | 670 | 670 | 678 | 678 | 770 | 980 |
| D | 690 | 872 | 872 | 872 | 946 | 946 | 946 | 1050 | 946 | 946 | 946 | 1092 | 997 | 1054 | 1153 | 1260 |
| E | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 180 | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 150 (152) | 180 | 180 | 200 |
| F | 65 | 65 | 65 | 65 | 75 | 75 | 75 | 90 | 75 | 75 | 75 | 75 | 70 | 70 | 75 | 250 |
| G | 200 | 200 | 200 | 200 | 180 | 180 | 180 | 325 | 180 | 180 | 180 | 180 | 184 | 184 | 180 | 588 |
| H | 930 | 930 | 930 | 930 | 1000 | 1000 | 1000 | 1230 | 1000 | 1000 | 1000 | 1137 | 1287 | 1372 | 1100 | - |
| CH | 220 | 220 | 220 | 220 | 255 | 255 | 255 | - | 255 | 255 | 255 | 255 | 256 | 256 | 305 | - |
| I | 190 | 190 | 190 | 190 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 240 | 256 | 256 | 290 | 250 |
| J | 6/4" | 6/4" | 6/4" | 6/4" | 6/4" | 6/4" | 2" | 2" | 6/4" | 6/4" | 6/4" | 2" | 2" | 2" | 2" | 2" |
| Typ ATMOS |
DC 15 E |
DC 18 S |
DC 22 S |
DC 25 S |
DC 32 S |
DC 40 SX |
DC 50 S |
DC 70 S |
DC 20 GS |
DC 25 GS |
DC 32 GS |
DC 40 GS |
DC 50 GSX |
DC 70 GSX |
DC 75 SE |
DC 100 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating power interval (kW) | 14,9 | 14- 20 |
15- 22 |
20- 25/27 |
25- 35 |
30- 40 |
35- 49 |
70 | 15- 20 |
20- 25 |
25- 35 |
30- 40 |
35- 49 |
70 | 75 | 99 |
| Required chimney Exhausted (Pa) | 18 | 20 | 23 | 23 | 24 | 24 | 25 | 30 | 20 | 23 | 25 | 25 | 25 | 30 | 30 | 35 |
| Boiler weight (kg) | 280 | 265 | 324 | 326 | 366 | 368 | 433 | 515 | 343 | 431 | 436 | 485 | 538 | 571 | 700 | 780 |
| Water volume (l) | 45 | 45 | 58 | 58 | 80 | 80 | 89 | 93 | 64 | 80 | 80 | 90 | 120 | 132 | 190 | 294 |
| Fuel container volume (dm3) | 65 | 66 | 100 | 100 | 140 | 140 | 180 | 180 | 85 | 125 | 125 | 170 | 210 | 210 | 345 | 400 |
| Max. length of wood (mm) | 330 | 330 | 530 | 530 | 530 | 530 | 730 | 730 | 330 | 530 | 530 | 530 | 530 | 530 | 1000 | 730 |
| Typ. consumption in season (m3) | 15 | 20 | 22 | 25 | 35 | 40 | 50 | 70 | 19 | 25 | 32 | 40 | 50 | 70 | 75 | 99 |
| Required fuel | Dry wood with specific energy 5-18 MJ/kg, diameter 80 - 150 mm, 12 - 20% water contents | |||||||||||||||
| Min. return water temperature | 65 °C | |||||||||||||||
| Efficiency in the operating power interval | 81 - 90 % | |||||||||||||||
| CLASS OF BOILER EN 303-5 | 3 | 3 | 3 (4) | 3 (4) | 3 (4) | 3 (4) | 3 (4) | 3 | 3 | 3 (4) | 3 (4) | 3 (4) | 3 (5) | 3 (4) | ||
Attention! The DC15E boiler is not equipped with a ventilator!
Boilers DC70S and DC100 are equipped with a blowing ventilator.